The PS 2.5 kW inverter/charger is available in 12- and 24-volt
models and includes a fully automatic three-stage battery charger.
|
|
Electrical
Specifications |
|
|
AC input
voltage |
|
120 VAC |
|
|
AC input
voltage range (default) |
|
108 - 132
VAC |
|
|
AC input
current (via slector switch) |
|
30 or 50
amps |
|
|
Continuous
Power @ 25°C |
|
2500 VA |
|
|
Efficiency
(Peak) |
|
90% |
|
|
Output
voltage (RMS) |
|
120 VAC |
|
|
Output
voltage regulation (typical) |
|
+/- 3% |
|
|
Frequency
(Nominal) |
|
60 Hz |
|
|
Continuous
output @ 25°C |
|
21 amps AC |
|
|
Surge
capability: |
|
|
|
|
5 sec
rating (resistive) |
|
5000 watts |
|
|
1 mSec |
|
69 amps AC |
|
|
100 mSec |
|
35 amps AC |
|
|
DC input
voltage (Nominal) |
|
12 VDC |
|
|
DC input
voltage range |
|
11.8 - 16.5
VDC |
|
|
DC current
at rated power |
|
275 amps DC |
|
|
Idle
consumption |
|
< 20 watts |
|
|
Search mode
consumption |
|
< 0.5 watts |
|
|
Max. charge
rate (adjustable) |
|
130 amps DC |
|
|
Total
Harmonic Distortion |
|
3 -5 %
Stand alone operations |
|
|
Waveform |
|
Sine wave,
34 to 52 steps per cycle |
|
|
Load
Sensing (Inverter Mode) |
|
Adjustable
0 to 240 watts (48 watts default) |
|
|
|
|
|
Specified
temperature range |
|
32°F -
104°F (0°C - 40°C) |
|
|
Enclosure
type |
|
Fully
screened, indoor, ventilated, steel chassis with powdercoat finish |
|
|
Unit weight |
|
80 lb (36.4
kg) |
|
|
Shipping |
|
88 lb (40
kg) |
|
|
Inverter
dimensions (H x W x D) |
|
15.5 x 22.5
x 6.5" (38.7 x 57.1 x 16.6 cm) |
|
|
Shipping
dimensions (H x W x D) |
|
20 x 26 x
12.75" (51 x 66 x 32.3 cm) |
|
|
Mounting
|
|
Vertical
wall mount or shelf mount |
|
|
Warranty |
|
Two years |
|
|
Part
Numbers |
|
PS2512 |
|
|
Features &
Options |
|
|
Forced air
cooling |
|
Standard
variable speed brushless DC fans |
|
|
Three-stage
charging |
|
Standard
three-stage (bulk, absorption, and float) |
|
|
Communications adaptor |
|
SWCA -
optional adaptor allows PC or modem connection |
|
|
Battery
Temperature Sensor |
|
BTS -
standard remote battery temperature sensor for increased battery performance |
|
|
Remote
Control |
|
SWRC -
optional remote control and status indicator or RC8 - optional on/off remote
control with status LED indicator |
|
|
Stacking
Interface |
|
SWI -
optional for series stacking of two identical PS units for 120/240 VAC
output - not available on E models |
|
|
Paralleling
Kit |
|
SWI/PAR or
SWI/PAR/E - optional for paralleling two identical PS units for twice the
power output |
|
|
Conduit Box |
|
PSCB -
optional side mount conduit box for code-compliant DC wiring connections |
|
|
Generator
Start |
|
GSM -
optional Generator Start Module allows auto generator start |
|
|
Auxiliary
Relay |
|
ALM -
optional Auxiliary Load Module provides voltage controlled relays |
|
|
Regulatory
Approvals |
|
|
UL Listed
to UL 1741 and cUL 107.1-95 and CE compliant |
|
|
|
Note:
Specifications subject to change without notice. |
|
|